Home / Humidifier pads

Guide

Whole-house humidifier pad sizes (water panels)

A humidifier water panel (evaporator pad) is not a furnace air filter. Order by the pad part number or humidifier model on the unit sticker — AprilAire panels 10 / 12 / 35 / 45 and Honeywell Home pads in the HC22 / HC26 families are the common retail lines. Nominal face size is smaller than a return grille filter (often ~10×10 or ~10×13), and it is almost never the same SKU as your furnace filter size.

Pad vs furnace air filter

Do not substitute a 1-inch furnace filter for a humidifier pad, and do not assume “10” on an AprilAire water panel means a 10-inch square return filter. Wrong part = poor humidification or a physical no-fit.

This page is equipment and fit care, not medical advice or health cures. We do not invent humidity health outcomes.

How to identify the pad from the sticker

  1. Find the humidifier cabinet — usually a metal box on the furnace / air-handler plenum or a bypass duct connection. It is separate from the return-filter grille.
  2. Read the unit model on the nameplate (examples: AprilAire 600, 700, 400; Honeywell Home HE220, HE260).
  3. Match the water-panel / pad part from the manufacturer chart (tables below), or from the printed number on the old pad frame if it is still readable.
  4. If the pad print is gone — use the unit model first. Measuring alone is a last resort; many pads share similar faces (35 vs 45 both list a 13×10×2 nominal) but are different materials and not interchangeable.
  5. Turn humidification off and shut the water supply before opening the cover. Follow the carton / owner’s manual for your exact series (AprilAire notes unique steps by model).

AprilAire’s own change guide lists water panels 10, 12, 35, or 45 for the classic evaporative lineup. Newer HydroCore / HYDROL cartridges are a different product family — if your box says HydroCore, do not assume a classic 10/35 pad fits.

AprilAire water panels (verified shop specs)

Dimensions below are from AprilAire shop product pages (accessed 14 Sep 2026). Height × width × depth as AprilAire prints them.

Water panel Nominal (in.) Published actual (in.) Fits humidifier models (OEM list) OEM change cadence
AprilAire 10 10H × 10W × 2D 9.75H × 9.5W × 1.75D 110, 220, 500, 500A, 500M, 550, 550A, 558 (plus 500MKZ / 500KZ variants on shop list) Once per heating season
AprilAire 12 15H × 12W × 2D 14.75H × 11.5W × 1.75D 112, 136, 224, 440, 445, 445A, 448 (shop also lists Chippewa 224 / 225; product title also names 225) Once per heating season
AprilAire 35 13H × 10W × 2D 13H × 10W × 1.75D 300, 350, 360, 560, 560A, 568, 600, 600A, 600M, 700, 700A, 700M, 760, 760A, 768 (plus KZ / MKZ variants on shop list) Once per heating season
AprilAire 45 13H × 10W × 2D 12.875H × 9.875W × 1.75D 400, 400A, 400M (plus 400KZ / 400MKZ on shop list) Twice per heating season

35 vs 45: same nominal 13×10×2 label family, different published actual and materials (35 aluminum / synthetic fiber; 45 paper-wicking with aluminum). Order by part number for the 400 series — do not “eyeball swap” a 35 into a 400.

Not verified as AprilAire water-panel part numbers: standalone “50 / 51 / 55 / 60” panels did not appear on AprilAire’s water-panel collection or the classic 10/12/35/45 shop SKUs we fetched (14 Sep 2026). If a merchant lists those digits, confirm against the unit model sticker before buying. Assembly kits such as H510EZ1A (500 series), H635EZ1A (600), H735EZ1A (700), and H445EZ1A (400) are full tray/pad assemblies that include a classic panel — not separate “model 50” pads.

Honeywell Home humidifier pads (verified)

Honeywell Home / Resideo sell evaporative pads mainly in two size families. Specs below are from Honeywell Home product pages (accessed 14 Sep 2026). Exact SKU letters (A / E / P) mark standard vs antimicrobial coatings — match the pad your manual names.

Pad family Common SKUs Published size (Honeywell Home) Fits humidifier models (OEM list)
HC22 (~10×10 class) HC22A1007, HC22E1003, HC22P1001/U line About 10H × 9.5L × 1.5–1.63W in. (product tables) Honeywell Home HE100, HE150, HE220, HE225; Honeywell Home also lists Aprilaire 110, 220, 550, 558 on the HC22 pad page
HC26 (~10×13 class) HC26A1008, HC26E1004, HC26P1002/U line About 10H × 13.13L × 1.5W in. (HC26P1002/U table) Honeywell Home HE200, HE250, HE260, HE265, HE300, HE360, HE365; Honeywell Home also lists Aprilaire 350, 360, 560, 568, 600, 700, 760, 768 on the standard HC26 pad page

Cross-brand listings mean a Honeywell-branded pad may physically match some AprilAire cabinets in the same size class — but AprilAire still publishes its own 10 / 35 part numbers for those models. Prefer the pad stamped on your unit or the OEM chart for that brand. We did not invent third-party “universal” SKUs.

Honeywell change cadence (manufacturer support): replace the humidification pad annually at the start of the heating season; with hard water, Honeywell notes you may need a mid-season replacement. Separate bypass-humidifier FAQ wording: replace pads once every season.

Change intervals (manufacturer-style only)

Season changes are a useful reminder to open both the return air filter and the humidifier cover — they are different maintenance items. Furnace-filter calendar: seasonal change reminder · thickness bands: how often.

What NOT to do

Where to look next (no pack prices)

We may earn a commission if you buy through links on this page. It does not change the price you pay.

This guide does not list dollar prices — humidifier pad packs move often. Use the model tables above, then open manufacturer charts or merchant results for the exact part number. Price-free external references we fetched:

Full policy: disclosure.